1. Direct current should be used during welding, and the negative electrode should be connected to one end of the welding wire.
2. Argon with a purity of 99.99% should be used as the protective gas, and when the current is between 50-150A, the argon flow should reach 8-10 liters per minute, and when the current is between 150-250A, the argon The flow should reach 12-15 liters per minute.
3. Oil stains, rust and other dirt on the welding part should be removed before welding to avoid welding pores.
4. During the welding process, the ventilation of the working environment should be maintained, and ventilation should be paid attention to indoors. At the same time, the shielding net must be used for protection during welding.
5. During the welding work, the angle between the welding part and the center line of the tungsten electrode should be kept between 80-85°. The advantage of this is to better protect the welding pool. The angle between the filler wire and the welding surface should be kept within 10°.