Quality requirements and safety measures for high-strength bolts

Mar 08, 2024

Leave a message

1. Surface rust, oil stains, burrs on the bolt hole wall, welding flash, etc. should be cleaned up.

2. The contact friction surface must meet the specified anti-scratch coefficient requirements after treatment. The high-strength bolts used should have matching nuts and washers. They should be used as matching sets and must not be interchanged.

3. When installing the friction surface of the treated components, oil, dirt and other debris are not allowed to be stained.

4. The friction surface of the component should be kept dry during installation and should not be operated in the rain.

5. Strictly check and correct the deformation of the connected steel plates before installation.

6. It is prohibited to hammer into the bolts during installation to prevent damage to the bolt threads.

7. Regularly test the electric wrench when using it to ensure the accuracy of the torque and operate it in the correct tightening sequence.

Main safety technical measures

1. The spanner size of the adjustable wrench should match the size of the nut. Small wrenches should not be used to add casings. A dead wrench should be used when working at heights. If an adjustable wrench is used, it should be tied tightly with a rope, and people should fasten their seat belts.

2. When assembling the connecting bolts of steel components, it is strictly forbidden to insert the connecting surface or explore the screw holes with your hands. When picking up and placing the iron pads, your fingers should be placed on both sides of the iron pads.

Send Inquiry